The study of monitoring grass bacteria and its influencing factors in the air of dorms of college students
-
摘要: 目的 了解大学生宿舍空气微生物污染状况,探讨影响大学生宿舍空气细菌总数的因素,为制订提高学生宿舍空气卫生质量的措施提供依据。方法 采用自然沉降法对西藏大学新校区96间宿舍进行空气细菌总数监测。结果 西藏大学学生宿舍空气中细菌总数总超标率为17.71%;下午大学生宿舍空气细菌总数944(553~1 573)cfu/m3多于上午472(157~1 376)cfu/m3;男生宿舍空气细菌总数超标率(27.08%)高于女生宿舍(8.33%);感官卫生状况良好的宿舍空气细菌总数超标率(3.45%)低于感官卫生状况较差者(38.89%),随感官卫生状况的改善空气细菌总数超标率降低(rs=0.314,P=0.002);摆放有绿色盆景的宿舍空气细菌总数超标率(6.25%)低于无绿色盆景的宿舍(23.44%);宿舍内存在异味时,宿舍空气微生物污染加重;不同楼层,大学生宿舍空气细菌总数超标率随楼层升高而降低(rs=-0.329,P=0.001)。结论 大学生宿舍空气细菌总数超标率与居住者性别、楼层、时间、感官卫生状况、宿舍内是否有异味及是否摆放有绿色盆景有关,需采取综合防治措施,降低大学生宿舍空气中细菌总数。Abstract: Objectives To know the condition polluted by air microbes in the dorms of college students,and to find the factors that influencing gross bacteria in the air of college students' dorms, in order to provide the basis for promoting the air quality of students'dorms. Methods Natural sedimentation was adopted to monitor grass air bacteria in 96 dorms at the new campus of Tibet University. Results The gross air bacteria over-standard rate was 17.71% in the dorms of college students at Tibet University.The gross air bacteria of the afternoon was 944(553-1 573)cfu/m3,which was more than that of the morning 472(157-1 376)cfu/m3.The gross air bacteria over-standard rate of boys'dorms was 27.08%,which was higher than that of girls' dorms(8.33%). The gross air bacteria over-standard rate in good condition of sense health was 3.45% better than that in worse condition of sense health (38.89%). With the improvement of the sense health,the gross air bacteria over-standard rate was reduced(rs=0.314,P=0.002).The gross air bacteria over-standard rate in dorms that have green plants was 6.25% better than the dorms without green plants (23.44%). There was more pollution by air microbes when there was a peculiar smell in the dorms.On the different floors, the gross air bacteria over-standard rate in dorms of college students can be decreased with storey.The higher you live in, the lower the gross air bacteria over-standard rate in dorms of college students was (rs=-0.329,P=0.001). Conclusions The gross air bacteria over-standard rate of college students relate to sex,storey,time,condition of sense health,whether existing peculiar smell and putting green plants.We should adopt comprehensive control measures to reduce the gross air bacteria in the dorms of college students.
-
Key words:
- Air /
- Bacteria /
- Epidemiologic studies
-
卢祖沟,刘军安,夏挺松. 农村社区卫生服务实践回顾与思考 [J]. 中国全科医学, 2002,5(2):85-87. 杨克敌. 环境卫生学 [M]. 第6版. 北京:人民卫生出版社, 2007. 张朝武. 卫生微生物学 [M]. 第4版. 北京:人民卫生出版社, 2007. 张征. 环境评价学 [M]. 北京:高等教育出版社, 2004. 凌琪,王敏. 高校学生宿舍空气细菌总数监测 [J]. 环境与健康杂志, 2005,22(1):78. 姚应水,芮光来,操基玉. 大学生宿舍空气中细菌污染及影响因素研究 [J]. 中国学校卫生, 2001,22(1):82-83. 车凤翔. 空气生物学原理及应用 [M]. 北京:科学出版社, 2004. 王跃,杨涛,任宴梅,等. 成都市某高校室内空气细菌污染的监测与分析 [J]. 成都医学院学报, 2009,4(4):295-297. 王立,钟有添. 大学生宿舍空气微生物污染的调查分析 [J]. 赣南医学院学报, 2010,30(2):243-244. 刘延秋,赵子爱,王猷金,等. 某部幼儿园消毒设备和卫生学调查 [J]. 中国公共卫生, 2005,11(9):416. Zhu H, Phelan PE, Duan TH, et al. Experimental study of indoor and outdoor airborne bacterial concentrations in Tempe Arizona,USA [J].Aerobiologia, 2003,19(3):201-211.
点击查看大图
计量
- 文章访问数: 340
- HTML全文浏览量: 64
- PDF下载量: 114
- 被引次数: 0